Seccua X-Spot® Pro

Designed to reduce all pathogenes and simultaneously remove turbidity from your drinking water - intelligently and cost-effectively

 

Characteristics

  X-Spot Pro 500 X-Spot Pro 1000
Performance data  
Filtration performance1 17 liter/min (4.6 gal/min) 36 liter/min (9.5 gal/min)
Removal performance (DHS approved)2  
Viruses > 99,99 %
Bacteria > 99,9999 %
Typical Water Consumption for Cleaning less than 2 %
Operating conditions    
Max. operating pressure 5 bar (75 psi)
Max. operating temperature 40 °C (104 °F)
Cleaning cycles Forward Flush by time, time interval or automatically based upon filter fouling
Maximum allowable differential pressure 2,5 bar (36 psi)
SeccuMem® Membrane filter  
Membrane fiber Extra strong hollow fiber
Nominal pore size 15 Nanometer (10-6 mm)
Certifications NSF 61 (USA)
DVGW-KTW Recommendation (Germany)
Dimensions  
Width 149 mm (5.9 in)
Depth 149 mm (5.9 in)
Height 768 mm (30,2 in) 1.268 mm (49.9 in)
Power supply  
Voltage 12 V DC, 110 - 230 V (AC)
Power consumption 1,5 W (filtration), 5,4 W (flushing)


 

 

Seccua X-Spot Pro

Virex X-Spot

 

 

Notes

1Filtration performance measured at 3 bar (45 psi) differential pressure and 10°C water temperature using clean city water.

2Virus and Bacteria removal of the Ultrafiltration membrane was measured under supervision of the Californian Department of Health Services (USA). Rejection rating measured while filtering surface water containing MS2-Phages, Giardias and Cryptosporidium. The rejection capability of the unit may decrease due to fiber breakage caused by improper operation or material aging. In order to ensure sustainable pathogenic removal of the unit it is recommended to regularly inspect the filter elements for fiber integrity.